S

YSTEM

O

PERATION

: E

QUIPMENT

P

OWER

R

EQUIREMENTS

0 2. 3 0 0 4. 0 3 00 . 5 4

23

1

Power Metering

WARNING: Power metering and connection to a house AC service should only be performed by
qualified personnel. This personnel is typically a "house electrician" supplied by the venue or other
contract electrician supplied by the venue for this purpose. This manual does not supply
procedures for metering a house AC service nor does it imply that persons using this equipment
are required to meter any type of house AC service.

Equipment

120 Volts Phase to

Neutral60 Hz Wye

Mode

208 Volts Phase to

Phase60 Hz Delta

Mode

240 Volts

Phase to Neutral

l50 Hz Wye Mode

VL2C Luminaire

11.0 amps

6.5 amps

6.3 amps

VL4 Luminaire

8.0 amps

4.8 amps

4.5 amps

Smart Repeater

9.6 amps

5.2 amps

6.0 amps

Smart Repeater Plus

12.8 amps

7.2 amps

6.5 amps

DMX200

1.0 amps

0.2 amps

0.3 amps

SPC-36 Controller

1.0 amps

0.2 amps

0.3 amps

APS6 Module (400W)

6.7 amps

3.7 amps

3.6 amps

APS6 Module (625W)

9.5 amps

5.5 amps

5.1 amps

APS6 Module (700W)

11.5 amps

5.8 amps

7.4 amps

C3 Module (1000W)

N/A

4.7 amps

4.3 amps

C3 Module (1200W)

N/A

5.2 amps

5.1 amps

DMX Power Pack

10.0 amps

6.0 amps

5.0 amps