b. For newer APS6 modules, a four position rotating switch on the face plate sets the

output to 400, 625, or 700 watts (the fourth setting is also currently 400W).
1) Set mode switch to either PSET or DCV.

CAUTION: Do not change mode or wattage with power applied to module.

2) Using 3/32 slot screwdriver (07.3005.0001), rotate power selector switch to

required output according to settings listed on face plate.

Step 4. Configure C3 modules.

The C3 module can be configured in two different output modes to accommodate both the
1000 watt and 1200 watt versions of the 120V incandescent lamps use with the VL5 and
VL5B luminaires. The 8.33 mode is used with 1000W/120V lamps and the 10.0A mode is
used with 1200W/120V lamps. A 0W shunt (blue programming jumper) installed at PCB
determines the mode.
a. At PCB, install 0W shunt (blue programming jumper) on header marked 8.33A for

1000W operation or 10.0A for 1200W operation.

Mode Switch

Power Switch

Power Switch Settings

8.33 10.0

JMP 2

Blue Programming

Jumper