7.4. Setting the Functions

Perform the following settings referring to the Basic Setting Operations on

p. 27

.

After connection completion of all cameras, turn on the power of cameras and the C-RM700, and initialize the
cameras. Then be sure to perform camera check after the camera's initialization operation has been
completed. (Refer to

p. 31

, "Camera check.")

7.4.1. Operation mode

Sets this unit's operation mode.

1. Press the Menu key for 3 seconds or more to display the menu screen.

2. Tilt the joystick up or down to select "OPERATION MODE," and confirm it with the SET key.

The setting contents will appear on Line 2.

3. Tilt the joystick left or right to select one of the following setting contents and confirm it with the SET key.

[Setting contents]

O P E R A T I O N M O D E

1 . M A S T E R

1

1. MASTER

Be sure to select Master when only a single C-RM700 unit is used. When 2 units are
connected, set either unit as the Master and the other as "SLAVE."

2. SLAVE

When 2 units are connected, set either unit as "SLAVE," and the other as "MASTER."

Note: Operation mode is set to "1. MASTER" by the factory.

7.4.2. Switchers

Sets the type of switcher to be connected to this unit.

1. Press the Menu key for 3 seconds or more to display the menu screen.

2. Tilt the joystick up or down to select "SWITCHER," and confirm it with the SET key. The setting contents

will appear on Line 2.

3. Tilt the joystick left or right to select one of the following setting contents and confirm it with the SET key.

[Setting contents]

S W I T C H E R

1 . 1 6 I N P U T

1

1. 16 INPUT

Select when the 16 channels Multi-Switcher is connected to the switcher control
terminal (RS-485) or a switcher is not connected to the terminal.

2. 9 INPUT A

Select when the 9 channels Multi-Switcher is connected to the switcher control
terminal (RS-485) and Camera 9's 4-segment split-screen display is set for "OFF" in
the Multi-Switcher settings.

3. 9 INPUT B

Select when the 9 channels Multi-Switcher is connected to the switcher control
terminal (RS-485) and Camera 9's 4-segment split-screen display is set for "ON" in
the Multi-Switcher settings.

Note: The switcher type is set to "1. 16 INPUT" by the factory.