7.4.19. Alarm function

Sets the camera image monitor method to be used when an alarm signal is received.

1. Press the Menu key for 3 seconds or more to display the menu screen.

2. Tilt the joystick up or down to select "ALARM FUNCTION," and confirm the selection with the SET key.

The setting will appear on Line 2.

3. Tilt the joystick to the left or right to select either of the following settings, and confirm it with the SET key.

[Setting contents]

A L A R M

F U N C T I O N

1 . S E Q

1

2. LAST

The output of the camera corresponding to the last received alarm signal is
displayed on the monitor in full-screen display.

1. SEQ (sequence)

Sequences the alarm-activated camera outputs to the monitor in full-screen display
in the order of alarm signal reception.

Note: This selection is set to "1. SEQ" by the factory.

7.4.20. Alarm hold

Always places alarm signal input to the surveillance camera system on hold.

1. Press the Menu key for 3 seconds or more to display the menu screen.

2. Tilt the joystick up or down to select "ALARM HOLD," and confirm the selection with the SET key.

The setting will appear on Line 2.

3. Tilt the joystick to the left or right to select either of the following settings, and confirm it with the SET key.

[Setting contents]

A L A R M H O L D

1 . K E Y

1

1. KEY

Permits the alarm to be held or reset using the unit's front panel-mounted keys.
(Refer to

p. 24

, "Alarm Hold and Reset.")

2. ALWAYS

Always places the alarm on hold when an alarm signal is input. Select this setting
when it is not desirable to have the screen automatically switched every time an
alarm signal is received.

Note: This selection is set to "1. KEY" by the factory.