Cisco 15327 User Manual

Page 72

Advertising
background image

4-6

Ethernet Card Software Feature and Configuration Guide, R7.2

Chapter 4 Configuring Interfaces

Configuring the Gigabit Ethernet Interface for the ML1000-2

Configuring the Gigabit Ethernet Interface for the ML1000-2

To configure IP address or bridge-group number, autonegotiation, and flow control on an ML1000-2
Gigabit Ethernet interface, perform the following procedure, beginning in global configuration mode:

Note

The default setting for the negotiation mode is auto for the Gigabit Ethernet and Fast Ethernet interfaces.
The Gigabit Ethernet port always operates at 1000 Mbps in full-duplex mode.

Step 3

Router(config-if)# flowcontrol send {on |

off

| desired}

(Optional) Sets the send flow control value for an
interface. Flow control works only with port-level
policing. ML-Series card Fast Ethernet port flow
control is IEEE 802.3x compliant.

Note

Since Fast Ethernet ports support only
symmetric flow control the flowcontrol
send
command controls both the receive
and send flow control operations.

Step 4

Router(config-if)# no shutdown

Enables the interface by preventing it from
shutting down.

Step 5

Router(config)# end

Returns to privileged EXEC mode.

Step 6

Router# copy running-config startup-config

(Optional) Saves your configuration changes to
TCC2/TCC2P flash database.

Command

Purpose

Command

Purpose

Step 1

Router# interface gigabitethernet

number

Activates interface configuration mode to
configure the Gigabit Ethernet interface.

Step 2

Router(config-if)# {ip address

ip-address

subnet-mask | bridge-group

bridge-group-number}

Sets the IP address and subnet mask.

or

Assigns a network interface to a bridge group.

Step 3

Router(config-if)# [no] negotiation auto

Sets negotiation mode to auto. The Gigabit
Ethernet port attempts to negotiate the link with
the partner port.

If you want the port to force the link up no matter
what the partner port setting is, set the Gigabit
Ethernet interface to no negotiation auto.

Step 4

Router(config-if)# flowcontrol {send |

receive

} {on | off | desired}

(Optional) Sets the send or receive flow control
value for an interface. Flow control works only
with port-level policing. ML-Series card Gigabit
Ethernet port flow control is IEEE 802.3z
compliant.

Step 5

Router(config-if)# no shutdown

Enables the interface by preventing it from
shutting down.

Advertising