No] pos report alarm – Cisco 15327 User Manual

Page 482

Advertising
background image

A-8

Ethernet Card Software Feature and Configuration Guide, R7.2

Appendix A Command Reference

[no] pos report alarm

[no] pos report alarm

Use this command to specify which alarms/signals are logged to the console. This command has no
effect on whether alarms are reported to the TCC2/TCC2P and CTC. These conditions are soaked and
cleared per Telcordia GR-253. Use the no form of the command to disable reporting of a specific
alarm/signal.

Syntax Description

Defaults

The default is to report all alarms.

Command Modes

Interface configuration mode (POS only)

Usage Guidelines

This value is normally configured to match the setting on the peer PTE.

Examples

In this example, interface is shortened to int.

Gateway(config)# int pos0

Gateway(config-if)# pos report all

Related Commands

pos trigger defects

Parameter

Description

alarm

The SONET/SDH alarm that is logged to the console. The alarms are as
follows:

all—All link down alarm failures

ber_sd_b3—PBIP BER in excess of signal degrade (SD) threshold failure

ber_sf_b3—PBIP BER in excess of signal fail (SF) threshold failure

encap—Path signal label encapsulation mismatch failure

pais—Path alarm indication signal failure

plop—Path loss of pointer failure

ppdi—Path payload defect indication failure

pplm—Payload label mismatch path

prdi—Path remote defect indication failure

ptim—Path trace indicator mismatch failure

puneq—Path label equivalent to zero failure