rpr-ieee pdi holdoff time interval

rpr-ieee pdi holdoff time interval

Use this command to configure the interval that occurs before a path defect indication (PDI) is raised on
an IEEE 802.17b based RPR span.

Syntax Description

Defaults

The default is 100 milliseconds.

Command Modes

IEEE 802.17b based RPR interface configuration

Usage Guidelines

This command can be used to prevent holdoff timer switching if a PDI is raised on an IEEE 802.17b
based RPR span. The PDI is an infrequent occurrence in this kind of span configuration.

Examples

In this example, interface is shortened to int.

Router(config)# int prp-ieee 0

Router(config-if)# rpr-ieee pdi holdoff time 100

Related Commands

None

Parameter

Description

interval

The period, expressed in milliseconds. The range is 100 to 1,000
milliseconds.