No] rpr-ieee shutdown {east | west – Cisco 15327 User Manual

Page 501

Advertising
background image

A-27

Ethernet Card Software Feature and Configuration Guide, R7.2

Appendix A Command Reference

[no] rpr-ieee shutdown {east | west}

[no] rpr-ieee shutdown {east | west}

This command is similar to a rpr-ieee protection request forced-switch {east | west} command on the
span. This command is essentially no different in function; it is an easier way to do the same thing.

Syntax Description

Defaults

Default is no shutdown.

Command Modes

IEEE 802.17b based RPR interface configuration

Usage Guidelines

Functionally, there is no difference between this command and the protection request commands.

In this command, shutdown can be shortened to shut.

Note

This command cannot be cleared by transitioning the span state from OOS,DSBLD (Locked,disabled)
to IS/IS,AINS/OOS,MT (Unlocked,enabled,automaticInService or Locked,maintenance).

Examples

In this example, interface is shortened to int.

Router(config)# int rpr-ieee 0

Router(config-if)# rpr-ieee shut east

Related Commands

None

Parameter

Description

east

Specifies a shutdown on the east span of the interface.

west

Specifies a shutdown on the west span of the interface.

Advertising