Weighing range function – A&D Weighing Indicator AD-4329 User Manual

Page 20

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

5.3. Weighing Range Function

The weighing range function can select "single range", "dual range” and "triple range".

Specify each weighing interval (division) for the multi-interval instrument Each

........ weighing interval is displayed according to a net value or gross value.

Caution a Using a single range, It 1^ not necessary to perform this function.

□ Perform the zero and span calibration after this function.

Example 1

The gross display.

Specified parameters:

First range

Second range

Third range

Display

0kg to 20kg:

20kg to 50kg:

60kg to 100kg:

Range = 20.00kg, division 0.01 kg

Range = 50.00kg, division 0.02kg

Range - 100.00kg (maximum capacity), division 0.1kg

The first range, division 0.01 kg.

The second range, division 0.02kg,

The third range, division 0.1 kg.

Division

Division

Division

0.1kg

0,02kg

I 1 1 It

0.01kg

TiirinTiniTi

■lili

0kg

20kg

50kg

100kg Gross

Weiging value

Example 2

The net display using a 40kg tare value.

Specified parameters:

The same parameters as example 1.

Display

-40kg to -20kg :

"20kg to 20kg :

20kg to 50kg :

50kg to 60kg :

The second range, division 0.02kg.

The first range, divisiion 0.01 kg.

The second range, division 0,02kg.

The third range, division 0.1 kg.

Division

Division

0.1kg

-40kg

Division

0.02kg

1

Division

0.01kg

iiiinrríTiTm

0.02kg

lilillitlllilill 1 I1Ì11

nrminif

-20kg 0kg

0kg

20kg

50kg 60kg Net

30kg

Tare vaiue

40kg

60kg

100kg Gross

Weighing value

5.3. Weighing Range Function