8. Accumulation

The function accumulates weighing data and stores sum of weight and count of

weighing. Data is stored in the EEPRQM, and is not lost even if the AC power

supply is disconnected.

8.1.1.

Preparation and Specification

Set the following parameters to use the accumulation function.

□ Select

[F - I I

/ for the CF-function so that the accumulation function becomes effective.

□ Specify the method of accumulation and data at F -04 of the F-f unction.

□ Specify the Inhibit range for accumulation at F-05 of the F-function.

key operation and

Selection of Accumulation Mode,

F-OH

of the F-function

□ There are two methods of manual accumulation, with the

automatic accumulation.

□ The accumulation data can select “positive data only" or "both polarity data".

Accurhulation Mode

F-OH

Data to accumulate

Manual accumulation mode

F-OH 0

Positive data only

F~iJH 1

Both polarity data

Automatic accumulation mode

F'OH г

Positive data only

F-DH 3

Both polarity data

Accumulation Condition, f-05 of the F-function

□ in case of manual accumulation mode, press the @ key to accumulate weighing

data when the MD mark turned off.

Data can be accumulated after weighing value becomes to the "inhibition region of

output". When connecting power cord and truning display on, the accumulation mode

makes the same action.

Inhibition region for accumulation

F-G5

Description

Add data anytime

F“05

0

Stable data can be used anytime

Above ±5 d

F"fl5 /

Factory setting

Above ±10 d

F“£J5 ?

Above ±20 d

F-05

3

Above ±50 d

F-05 4

Caution □ Do not set to f-05 0 for the automatic accumulation mode

□ If setting to F “05 0, it may add the same data two times or more.

Limitation of Accumulation Count and Total

□ The limitation of accumulation count is 999999.

The limitation of total is ±999999 ignoring the decimal point.

□ if exceeding these limitations, data is not accumulated.

Example: Setting the decimal point to second a figure like "0.0", the limitation is "99999.9".