1,7. related functions, Related functions – A&D Weighing Indicator AD-4329 User Manual

Page 53

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Set Zero band

Set the zero band value of the setpoint comparison. The decimal point is not

necessary because of according to display.

Templete

Command

Reply

S3, [value]

[s 3

A±mm_

Cpt|Lp|

fs IL

■fj

7\

4j 8|%|^|

12.1,7. Related Functions

F-Function

Description

Output Data

f~H0 0

Displayed data

F-HO 1

Gross data

F-HOS

Net data

F~HÜ3

Tare value

F-% H

Gross data / Net data / Tare value

Output mode

F-Funciion

Description

Stream mode

F-HIÜ

Description of “Stream Mode“ at page 31

Auto print mode

F-% 1

Description of "Auto Print Mode" at page 31

Manual print mode

F~^[j 3

When pressing the

print

key each time, the data is output once.

Command mode

(no address)

F-%3

Refer to "12.1.3.Command Format" of RS-232C interface.

Command mode

with address

Auto-print condition

F-Function

Description

Positive data only

F-H3 0

"inhibition regiori of output" ^*f5d.

-1-5D < "permission region of output".

Positive and
negative data

F-% 1

-5d ^ "inhibition region of output"

S

-fSd.

"Permission region of output" < -5d, +5d < "permission region of output".

F"Function

Description

Delay for continual
data

F-%ü

Not used

F-% 1

Approximately 2 seconds

Baud rate

600 bps, 1200 bps, 2400 bps, 4800 bps, 9600 bps

Data format

F-HS

Referto "12.1.2.Data Format" of RS-232C interface.

F-%

Address

BO

to

33

Factory setting is

BB,

When F - H 1 H

is not selected, f-% is ineffective.

CF-Functlon

Description

[F-Bl

Data output of tare

[F-B8

Output on over load and unstable state.

Use or not used

[F-B3

Format of Header

Selection of

TR, PT, GS, NT, T, G

and

N

l

F- IB

Figure number of unit, decimal point

Two figures or three figures, dot or comma

[F- II

Accumulation function

Effective or ineffective

AD-4329 Weighing Indicator

Page 49

12. RS-232C Interface

Advertising