9.3.

Setpoint Comparison

□ This function includes the weighing sequence and uses for getting preset target

weight.

□ There are four parameters of "Final", "Preliminary", "Free fall" and "Zero band" to

use the setpoint comparison.

□ The result of the sequence is output to three relays.

□ When inputting these parameters, it is not necessary to input the F-function

f-^0

again unless changing the F-function.

Caution □ This function is normal batching only and can not perform loss-in-

weight.

9.3.1.

Selecting Setpoint Comparison

step 1 Press the lOperaTe/Standbyl key to turn display off.

Press and hold the [MOPEl key and press the

Operaie/Standbvi key to enter the F-function mode.

Step 2 Select f-c’O c’ (setpointcomparison).

F-FunctiorLmode

Comparator function

/

Setpoirit comparison /

Step 3 Turn the display off using the [Operate/Standbyl key.

Display off

9.3.2.

Description of Input parameters and Outputs

Weighing value

a

SETO, Final

SET2, Preliminary

Tared Zero

Caribrated Zero

Preset target weight

Weighing trace

Relay HI, Net ^ {Final - Free fall)

OFF (Break)

ON (Make)

OFF (Break)

Relay OK, Net^ (Final - Preliminary)

OFF (Break)

|

ON (Make) OFF (Break)

Relay LO, Gross < Zero band

ON (Make) OFF (Break)

ON (Make)

Parameters List

SETO

Final

Set a preset target weight.

SETI

Free fall

Set a corrective value related to closing the dribble flow gate.

SET2

Preliminary

Set a begining point to use the dribble flow gate on!y.

SETS

Zero band

Set a value to regard as neariy zero.