1 0. External Control Input

□ The connector "EXT.IN" can be used to control the indicator from an external terminal

like a front panel key operation,

□ Set the external control function at f - /0 - f - / 7 of the F-Functlon.

□ When shorting each function pin and common pin, the Indicator makes the action.

Caution □ Keep a signal width more than 100 ms for the On-time and Off-time.

ON (Make)

OFF (Break)-I

More than 100ms More than 100ms

PhotoCoupier Relay, Switch

4J)C+5V

560Q

<^r~AAA^

! U

1,3,4,5,6,7,Spin

2pin

Common pin

The inside of AD-4329

Pin No.

F-Function Parameter

Description

0

Not used (No function)

1

Zero key

B

Tare key

3

Print key, ^ key

Ij

Operate/Standby key

1 pin

F ~

s

M+ key

EXT1

5

Net/Gross key

7

Mode key

e

Gross display when shorting terminal.

3

Accumulation data display when shorting terminal.

IÜ .

Over signal Gross over and display data are output.

II

All keys are enable when shorting terminal.

2

pin

Common pin for EXT1 EXT7.

3 pin

f~ II

The same

as F ~ 10

4 pin

F~lг

EXT3

The same as

F -

/3

5 pin

r- ii

EXT4

The same as F-

10

6 pin

f-

N

EXT5

The same as F ~ 10

7 pin

F " / 5

EXT6

The same

asF ~ ¡0

8 pin

F"

IB

EXT7

The same asF-

10

Case

Shield.

AD-4329 Weighing Indicator