Testing the direct-connect interface port – Denso BHT-7500 User Manual

Page 100

Advertising
background image

80

If any error occurs, the BHT beeps three times and
shows the screen at left.

In parentheses are error codes which have the
following meanings:

(X X)

1: The received data is different from

the sent data.

2: A timeout has occurred during

standby for data reception.

1: 300 bps
2: 115200 bps

Testing the direct-connect interface port

Selecting the "2:CONNECTOR" on the TEST COM-
MUNICATION menu displays the screen shown at
left and then starts testing the direct-connect in-
terface port.

Upon normal completion of the test, the tested
slave BHT beeps once and shows the screen at
left.

Press the C key to return to the TEST COMMUNI-
CATION menu.

The master BHT will automatically return to the
TEST COMMUNICATION menu.

TEST COMMUNICATION

< OPTICAL >

** Test OK **

TEST COMMUNICATION

< CONNECTOR >

** Testing **

TEST COMMUNICATION

< CONNECTOR >

** Test NG **

(XX)

Press the C key to return to the TEST COMMUNI-
CATION menu.