Denso BHT-7500 User Manual
Page 83
63
Chapter 2. Getting Started the BHT and System Mode
[4.5-2]
Setting the communications parameters for the direct-connect
interface
Selecting "2:CONNECTOR" on the SET COMMUNI-
CATION menu calls up the screen shown at left.
1 PARAMETER:
Switches to the commu-
nications parameters set-
ting screen.
2 PROTOCOL:
Switches to the commu-
nications protocol option
screen.
Select a desired screen by using the numerical
keys or
and
keys, and then press the
ENT key.
To return to the SET COMMUNICATION menu,
press the C key.
(1) Communications parameters setting screen
Selecting "1:PARAMETER" on the SET CONNEC-
TOR screen calls up the screen shown at left.
Highlighted is the current setting.
1 TRANSMIT SPEED:
Sets the transmission
speed.
2 PARITY BIT:
Sets the vertical parity:
none, odd, or even.
3 DATA BIT:
Sets the character length.
4 STOP BIT:
Sets the stop bit length.
Select a desired item by using the numerical keys
or
and
keys. Then select a desired setting
by using the
and
keys.
To return to the SET CONNECTOR screen, press
the C key.
If the BHT-Ir protocol has been selected, the
parity bit, character length, and stop bit length
settings will be ignored.
SET CONNECTOR
1:PARAMETER
2:PROTOCOL
SET PARAMETER
< CONNECTOR >
1:TRANSMIT SPEED:
300 600 1200
2400 4800 9600
19200
38400 57600
115200
2:PARITY BIT:
None
Odd Even
3:DATA BIT: 7bits
8bits
4:STOP BIT:
1bit
2bits