Section 5 ERROR CODES

5.1 Error Listing

The following is a listing of error codes generated by the PLS-2500 unit and suggested action for
correction of the errors. These codes apply to software version 1.8 and above.


Error No.

Message / Action

001

OIT UNABLE TO COMMUNICATE WITH LOGIC BOARD

1) Verify that Operator Interface Terminal cable is properly wired to the plug-in
terminal strip for Logic Unit.

2) Verify that plug-in terminal strip is securely installed into header (receptacle)
on Logic Unit.

3) Notify factory.

002

No message

1) Notify factory.

003

No message

2) Notify factory.

020

LOGIC BOARD HARDWARE FAILURE

1) Notify factory.

023

NO RESOLVER SIGNAL AT POWERUP

1) Verify that resolver cable round connector is securely installed to its mate on
rear of resolver package.

2) Verify that resolver cable is properly wired to plug-in terminal strip for Logic
Unit.