System 2500 Operating & Installation Manual - Revision 07

5-9

internal ON/OFF software switch MUST first be turned ON. If the AUTO SS
ENABLE input is activated (i.e., setup button pressed) before turning the Auto
Single Stroke feature ON, this error will be generated (see Section 2.8.4.2 above).

222

MACHINE DID NOT STOP WITHIN 20 DEGREES OF TOP - AUTO SS
UNLATCHED

When using the Automatic Single Stroke feature, the machine must ALWAYS
stop between 340 degrees and 20 degrees (i.e., within 20 degrees of top) or Auto
Single Stroke will be unlatched and this error will be generated. This includes
both the first manual stroke and all successive automatic strokes.

223

AUTO SS MINIMUM TIME BETWEEN STROKES EXCEEDS MAX TIME -
MUST RE-ENTER

The operator must enter a Minimum Delay Time between strokes and a Maximum
Delay Time between strokes (see Sections 2.8.4.5 and 2.8.4.7 above). The
maximum time must obviously be greater than the minimum time or this error
will be generated. Before attempting to clear this error the operator must first
enter valid times to satisfy this condition. (Note that the minimum time is entered
in milliseconds or thousandths of a second while the maximum time is entered in
seconds).

225

DIE PROTECTION FAULT

to
232

Error numbers 225 to 232 correspond to die-protection inputs 25 to 32
respectively.

1) Investigate the cause of the die protection fault on the indicated input.

243

NO DIE-PROT DATA PROGRAMMED!
WARNING! DIE-PROT IS NOT ACTIVE!

This error is intended to notify the operator that no die protection data has been
programmed in the current setup. Without any data programmed for die
protection, the System 2500 has no way of monitoring the die for undesirable
conditions. The following options can be chosen:

1) Reprogram the die protection inputs to their correct modes and reprogram all