5 • Optical Mark Recognition (OMR)

5-22

SV40221 Rev. C

OMR Scanner Adjustments

The machine can be fitted with one Top Scanner and one Bottom

Scanner. If the sheet(s) bearing OMR marks are loaded face up,

the Top Scanner will be used. If they are loaded face down, the

Bottom Scanner will be used. The loading orientation required for the

particular job will be shown on the Mail Piece Icon Tree and depends

on fold type, etc.

Aligning the Scanners

It is essential that the OMR Scanner being used is correctly aligned

over the OMR marks printed on the sheet(s) or Insert(s). Failure

to align the scanner will result in scanning errors. It is therefore

essential that the scanner alignment is checked before commencing

any OMR job.
Measure the OMR mark position

Take a sheet/Insert printed with the OMR marks to be used and

fold it in half in the direction of feed to locate the center line. Now

measure from the center lne to the center of the OMR marks in

millimeters. Take a note of this measurement (X).

X mm

Folded

center line

X mm

OMR marks

(position used

depends on

scanner location)

Advertising