Once the Bottom Scanner is aligned, the Top Scanner (or paper

guide if a corresponding Top Scanner is not fitted) must be

positioned so that the sheet being scanned is kept at a controlled

distance from the scanner.
This is achieved by adjusting the Top Scanner as described on page

5-23, but to a setting 10mm different to the Bottom Scanner setting.

For example, if the Bottom Scanner is set to 70mm, set the Top

Scanner to 80mm.

Top Scanner

Bottom

Scanner

10mm

60 70 80

Bottom

Scanner

position

Top Scanner

position

TIP:
If Selective Feed of sheets is being used in a Job

Definition using Single or Z Folds, the Selective Feed

Scanner will require adjustment as well as the Top and

Bottom Scanners. See page 5-27 for details.