Switching, Bridging – Signamax Model -065-7700 User Manual

Page 130

Advertising
background image

Hardened Managed PoE Ethernet Switch

User’s Manual 129

Switching

Bridging, Static MAC Entry, Port Mirroring, PoE, PoE Scheduling

Bridging
Aging Time (seconds):
1.

Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.

switch_a(config)#


2.

Usage:

Use this command to specify an ageing-out time for a learned MAC address.
The learned MAC address will persist till this specified time.

3.

Command Syntax:

Bridge GROUP ageing-time AGEINGTIME
no bridge GROUP ageing-time

Group = <1-1> The ID of the bridge-group that this ageing time is for.
AGEINGTIME = <10-1000000> The number of seconds of persistence.


4.

Example:

The following example sets the new AGEINGTIME (1000) to bridge GROUP
(1):

switch_a(config)#bridge 1 ageing-time 1000
switch_a(config)#


Threshold level (0-100):
1.

Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.

switch_a(config)#interface fe1
switch_a(config-if)#


2.

Usage:

Use storm-control level command to specify the rising threshold level for
broadcasting, multicast, or destination lookup failure traffic. The storm control
action occurs when traffic utilization reaches this level.

3.

Command Syntax:

storm-control level LEVEL

Advertising