Signamax Model -065-7700 User Manual

Page 164

Advertising
background image

Hardened Managed PoE Ethernet Switch

User’s Manual 163


Location:
1.

Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.

switch_a(config)#


2.

Usage:

Use snmp-server location command to specify and no snmp-server
location
command to remove location for SNMP.

3.

Command Syntax:

snmp-server location LOCATION
no snmp-server location

LOCATION The location for SNMP.


4.

Example:

The following example specifies location (location) for SNMP:

switch_a(config)#snmp-server location location
switch_a(config)#


Contact:
1.

Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.

switch_a(config)#


2.

Usage:

Use snmp-server contact command to specify and no snmp-server
contact
command to remove contact for SNMP.

3.

Command Syntax:

snmp-server contact CONTACT
no snmp-server contact

CONTACT The contact for SNMP.


4.

Example:

The following example specifies contact (contact) for SNMP:

switch_a(config)#snmp-server contact contact
switch_a(config)#


Trap Community Name:

Advertising