Poe scheduling – Signamax Model -065-7700 User Manual
Page 137
Hardened Managed PoE Ethernet Switch
User’s Manual 136
2.
Usage:
Use poe power-down-alarm enable command to enable power down alarm
to this port.
Use the no poe power-classification enable to disable this function.
3.
Command Syntax:
(no) poe power-down-alarm enable
4.
Example:
The following example shows the use of poe power-down-alarm enable to
the interface fe1 (port 1):
switch_a(config)#interface fe1
switch_a(config-if)#poe power-down-alarm enable
switch_a(config-if)#
PoE Scheduling
PoE Schedule:
1.
Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.
switch_a(config)#interface fe1
switch_a(config-if)#
2.
Usage:
Use this command to enble PoE scheduling to this port.
3.
Command Syntax:
poe schedule enable
4.
Example:
The following example enables PoE scheduling to the interface fe1 (port 1):
switch_a(config)#interface fe1
switch_a(config-if)#poe schedule enable
switch_a(config-if)#
PoE Schedule:
1.
Command Mode: Interface mode
Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.
switch_a(config)#interface fe1