Port authentication – Signamax Model -065-7700 User Manual

Page 174

Advertising
background image

Hardened Managed PoE Ethernet Switch

User’s Manual 173

The following example specifies 20 seconds for the Switch to wait for a server
host to reply before timing out:

switch_a(config)#radius-server timeout 20
switch_a(config)#


Retransmit:
1.

Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.

switch_a(config)#


2.

Usage:

Use this command to specify the number of times the Switch transmits each
radius request to the server before giving up.

3.

Command Syntax:

radius-server retransmit RETRIES
no radius-server retransmit

RETRIES <1-100> Specifies the retransmit value. Enter a value in the range
1 to 100.


4.

Example:

The following example specifies the retransmit value 12:

switch_a(config)#radius-server retransmit 12
switch_a(config)#


Port Authentication
Authentication State:
1.

Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.

switch_a(config)#interface fe1
switch_a(config-if)#


2.

Usage:

Use dot1x reauthetication command to enable reauthentication on a port.
Use no dot1x reauthetication command to disable reauthentication on a
port.

3.

Command Syntax:

(no) dot1x reauthentication

Advertising