Use this command to to set time zone.

3.

Command Syntax:

clock timezone TIMEZONE

TIMEZONE Specifies the time zone. (Please refer the Appendix B)


4.

Example:

The following example sets time zone (Canada/Yukon):

switch_a(config)#clock timezone YST9YDT
switch_a(config)#


Polling Interval:
1.

Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.

switch_a(config)#


2.

Usage:

Use this command to specify the polling interval.

3.

Command Syntax:

ntp polling-interval MINUTE

MINUTE <1-10080> The polling interval. Enter a value in the range 1 to
10080 minutes.


4.

Example:

The following example specifies the polling interval 60 minutes:

switch_a(config)#ntp polling interval 60
switch_a(config)#


Daylight Saving Mode:
1.

Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.

switch_a(config)#


2.

Usage:

Use this command to enable daylight saving.
Use no clock summer-time command to disable daylight saving.

3.

Command Syntax:

clock summer-time TIMEZONE weekday WEEK DAY MONTH HOUR
MINUTE WEEK DAY MONTH HOUR MINUTE OFFSET
TIMEZONE Specifies the daylight saving timezone.