Use this command to to set time zone.
3.
Command Syntax:
clock timezone TIMEZONE
TIMEZONE Specifies the time zone. (Please refer the Appendix B)
4.
Example:
The following example sets time zone (Canada/Yukon):
switch_a(config)#clock timezone YST9YDT
switch_a(config)#
Polling Interval:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to specify the polling interval.
3.
Command Syntax:
ntp polling-interval MINUTE
MINUTE <1-10080> The polling interval. Enter a value in the range 1 to
10080 minutes.
4.
Example:
The following example specifies the polling interval 60 minutes:
switch_a(config)#ntp polling interval 60
switch_a(config)#
Daylight Saving Mode:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to enable daylight saving.
Use no clock summer-time command to disable daylight saving.
3.
Command Syntax:
clock summer-time TIMEZONE weekday WEEK DAY MONTH HOUR
MINUTE WEEK DAY MONTH HOUR MINUTE OFFSET
TIMEZONE Specifies the daylight saving timezone.