Hardened Managed PoE Ethernet Switch

User’s Manual 167

Use snmp-server trap-type enable authenticationFailure command to
enable authentication failure trap for SNMP.
Use the no snmp-server trap-type enable authenticationFailure
command to disable authentication failure trap for SNMP.

3.

Command Syntax:

(no) snmp-server trap-type enable authenticationFailure

4.

Example:

The following example enables authentication failure trap for SNMP:

switch_a(config)#snmp-server trap-type enable authenticationFailure
switch_a(config)#


Topology Change Trap:
1.

Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.

switch_a(config)#


2.

Usage:

Use snmp-server trap-type enable topologyChange command to enable
topology change trap for SNMP.
Use the no snmp-server trap-type enable topologyChange command to
disable topology change trap for SNMP.

3.

Command Syntax:

(no) snmp-server trap-type enable topologyChange

4.

Example:

The following example enables topology change trap for SNMP:

switch_a(config)#snmp-server trap-type enable topologyChange
switch_a(config)#


SNMP v1/v2c
Get Community Name:
1.

Command Mode: Configure mode

Logon to Configure Mode (Configure Terminal Mode).
The switch_a(config)# prompt will show on the screen.

switch_a(config)#


2.

Usage:

Use snmp-server community get command to specify and no
snmp-server community get
command to remove get community name for
SNMP.