background image

Hardened Managed PoE Ethernet Switch

User’s Manual 155

fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.

switch_a(config)#interface fe1
switch_a(config-if)#


2.

Usage:

Use switchport mode hybrid command to set the switching characteristics
of the Layer-2 interface as hybrid, and classify both tagged and untagged
frames.
Use the no switchport hybrid command to reset the mode of the Layer-2
interface to access (default).

3.

Command Syntax:

switchport mode hybrid
switchport mode hybrid acceptable-frame-type all/vlan-tagged
no switchport hybrid
all Set all frames can be received.
vlan-tagged Set vlan-tagged frames can only be received.

4.

Example:

The following example sets the switchport mode hybrid of the interface fe1
(port 1) and all frames to be received on interface fe1 (port 1):

switch_a(config)#interface fe1
switch_a(config-if)#switchport mode hybrid acceptable-frame-type all
switch_a(config-if)#


Switchport mode trunk:
1.

Command Mode: Interface mode

Logon to Configure Mode (Configure Terminal Mode).
Then logon to Interface mode.
fe1 means port 1.
The switch_a(config-if)# prompt will show on the screen.

switch_a(config)#interface fe1
switch_a(config-if)#


2.

Usage:

Use switchport mode trunk command to set the switching characteristics of
the Layer-2 interface as trunk, and specify only tagged frames.

Use the no switchport trunk command to reset the mode of the Layer-2
interface to access (default).

3.

Command Syntax:

switchport mode trunk
no switchport trunk

4.

Example:

Advertising