Storage and location requirements – Beisler 2211-5 User Manual

Page 40

Advertising
background image

- C 40 -

Short Seam Automat 2211-5 Working Instructions

Beisler Automated Sewing Equipment

C.2

Storage and location requirements

C.2.1 Floor quality

The floor of the room where the machine is to be instal-
led must have a sufficient surface strength. The location
of the machine must be free of vibrations.
If several machines are to be installed in one room, the
static load bearing capacity of the ceiling must be consi-
dered.

Weight:

Machine with accessories

approx 210 kg

C.2.2 Interior climate

Climatic requirements for the operating room:
The machine must only be stored or operated in closed
operating rooms.

Room temperature

+10 °C to +45 °C

Relative humidity

80 % max.

C.2.3 Floor space required

For operation during production and for service works, the
machine must be freely accessible from all sides. On all
sides, there must be a minimum clearance of 1 m.

Machine dimensions:

L x W x H

1700 x 1200 x 1600 mm

NOTE - Electromagnetic interference!

The machine must not be installed in the immediate
vicinity of devices or electrical components (e.g. trans-
formers) generating a strong magnetic field as other-
wise the correct function of the program control may
be impaired.

C.2.4 Supply connections

The machine requires on-site power and compressed air
sources.

Power connection:
The power supply of the machine requires a properly
grounded power connection with:

Grounding plug

230 V ± 10 %, 50/60 Hz

Fusing

16 A

NOTE - Peak voltages!

The correct function of the machine requires that the
power system supplies a constant current. Peak vol-
tages may particularly impair the stability of the pro-
gram control.

Compressed air supply:
The on-site compressed air supply system must meet the
following requirements:

Operating pressure

6 bar

Compressed air quality

oil-free

Compressed air consumption

4.16 NL

Vacuum source:
The on-site vacuum source must meet the following re-
quirements:

Displacement (minimum)

130 m³/h