Short Seam Automat 2211-5 Working Instructions

- D 86 -

Beisler Automated Sewing Equipment

D.3

Programming

D.3.5 Service menu level 1

Terminal assignment for lock stitch (1-4):
S23 *Top thread monitor
Terminal assignment for chain stitch (5-8):
S24 *bottom thread monitor

Terminal assignment *plug X2:

yellow

1

green

2

white

3

brown

4

D.3.6 Global parameters

Global parameters are values that control the basic func-
tions of the machine. If global parameters are changed,
this change affects all stored sewing programs.
The minimum and maximum input values are limited by
the program control unit. Values that are not within the limits
will not be accepted but reduced to the corresponding
minimum or maximum value

„

„

„

„

„ Requesting / exiting the global parameter menu:
Change from service menu start level to level 1:



Press

 key.

&

Press

 key.

Browse through list:

Press

. or Y key.

Move to line in list:

Press

" or # key.

Change parameters:

Press

$ key.

Insert new value using numeric keypad or

Press

. or Y key.

Confirm input:

Press

$ key.

Exit menu and save changed parameter:

Press

W key.