Programming – Beisler 2211-5 User Manual

Page 87

Advertising
background image

- D 87 -

Short Seam Automat 2211-5 Working Instructions

Beisler Automated Sewing Equipment

D.3

Programming

D.3.7 List of global parameters

No.

Programmable global parameters (F2)

01

TILL CLAMP SIDEWAYS FWD:
Scan and part pickup after clamp movement forward / time interval

02

TILL CLAMP DOWN ......:
Lower clamp after clamp movement forward for part pickup / time interval

03

TILL VACUUM OFF ......:
Switch vacuum off after clamp down / time interval

04

THRD LENGTH,BOBBIN FULL
Length of thread of filled bobbin

05

TILL CLAMP INSERTING:
Clamp insertion delay / time delay

06

SEWING END ->CL.SIDEW.:
Clamp movement sideways rearward after sewing is completed / time interval

07

TIME AFTER CLAMP OPEN :
Clamp movement right to programmed position after clamp up / time interval

10

TILL FOLDING CL. CLOSED:
After folder right and down, time until folding clamp closes / time interval

11

TILL FOLDER LIFT UP...:
After folding clamp closes, time until folder up / time interval

12

TILL FOLDER SWINGS LEFT:
After folder up, time until folder swings left and rotates / time interval

13

IMPULS FOLDER DOWN ...:
Pulse duration folder down, time until folder is switched airless during pick-up / time delay

14

CL.OPEN TILL FOLDER UP:
After folding clamp opens, time until folder up / time interval

17

TILL TENSION OPEN ....:
After end of seam, time until tension blower on / time interval

18

DURATION OF TENS. OPEN:
ON duration for tension blower

19

TILL THREAD CLAMP FORW.:
After clamp up, time until thread clamp forward / time interval

20

DUR.THREAD CLAMP FORW.:
Duration of blowing and thread clamp forward

21

TILL STACKER TRANSPORT:
After sewing drive stops and transport stamp down, time until stacker transport moves backward to ES8 / time
interval

22

DUR.SLIDING TABLE OPEN:
Duration for sliding table open / time delay

23

LIFT.TABLE MOD 00/01-99:
Lower lift table, defaults:
Input 00: Lower lift table using photocell control
Input 01-99: Lift table is lowered after corresponding number of pieces

24

DUR.LIFTING TABLE SINKS:
Lower lift table / duration

25

TILL FABRIC CLAMP FORW.:
After footswitch is released, time until pocket bag clamp closes / time interval

Advertising