Short Seam Automat 2211-5 Working Instructions

Beisler Automated Sewing Equipment

C.5

Maintenance

C.5.5 Machine set-up

Photocell light sensitivity setting:
The photocell 1 at the sewing head controls the begin-
ning and the end of the sewing process, provided that this
function has been enabled as described in Section D.4.9.
The sensitivity of the photocell must be set in accordan-
ce with the sewing material used.
1. Fig. 24: Make sure that the light beam 2 of the pho-

tocell is not interrupted.

2. Unlock the keypad:

Keep the two buttons 5 and 6 (+ / -) depressed for
approx 5 seconds.
The green LED 8 illuminates momentarily to indicate
the unlocked state. The keypad remains unlocked for
4 minutes (red LED 7 flashes), then the light guide
controller is locked automatically.

3. Set sensitivity using buttons 5 and 6:

Press + to increase sensitivity.
Press - to reduce sensitivity.

4. Interrupt light beam 2 with the sewing material to be

used 3; if the yellow LED 9 fails to go off, reduce
sensitivity.

NOTE - Red LED!

The red LED 7

7

7

7

7 must not illuminate in any switching

state. If the red LED illuminates, the light amplifier is
in a critical switching state. In this case, increase the
photocell sensitivity until the red LED goes off, then
set the sensitivity in accordance with the sewing
material used as described above.