C.5.5 Machine set-up

Checking the rest thread monitor:
The rest thread monitor is checked using a photocell. If
the messages on the display do not match the filling state
of the spool, the photocell sensitivity must be checked.

1. Fig. 27: Fill bobbin to half its capacity so that filling state

indicators 2 of upper chamber 1 are covered.

2. Insert bobbin and sew until display shows: BOBBIN:

003 m.
Keep sewing until display shows: BOBBIN EMPTY

3. Remove spool, unwind rest thread and measure remai-

ning length (should be 0.5 m).

Adjusting the photocell:

If the thread on the spool is sewn off over the rest length
of 0.5 m without the message BOBBIN EMPTY being
displayed, the photocell sensitivity must be increased:

• Rotate potentiometer at photocell in clockwise di-

rection.

If the message BOBBIN EMPTY is displayed even
though the spool contains more than 0.5 m thread, the
photocell sensitivity must be reduced:

• Rotate potentiometer at photocell in counter-clo-

ckwise direction.

Fig. 27

Fig. 27