XR2500F Installation Guide

Digital Monitoring Products

23

InstallatIon

Protection Zones

16.1 Terminals 13–24

Zones 1 to 8 (terminals 13 to 24) on the XR2500F panel are all grounded burglary zones. For programming

purposes, the zone numbers are 1 through 8. Listed below are terminal 13 to 24 connection functions.

Terminal

Function

Terminal

Function

13

Zone 1 voltage sensing

19

Zone 5 voltage sensing

14

Ground for Zones 1 and 2

20

Ground for Zones 5 and 6

15

Zone 2 voltage sensing

21

Zone 6 voltage sensing

16

Zone 3 voltage sensing

22

Zone 7 voltage sensing

17

Ground for Zones 3 and 4

23

Ground for Zones 7 and 8

18

Zone 4 voltage sensing

24

Zone 8 voltage sensing

Note: Zones 1 and 2 have been pre-wired to the two 866 NAC modules. All other zones are available.
The voltage sensing terminal measures the voltage across a 1k Ohm End-of-Line resistor to ground. Use

DMP Model 311 1k Ohm resistors. Dry contact sensing devices can be used in series (normally-closed) or in

parallel (normally-open) with any of the burglary protection zones.

1K Ohm

Normally

Closed

1K Ohm

Normally Open

1K Ohm

Combination Normally Open

and Normally Closed

Figure 12: Protection Zone Wiring

16.2 Operational Parameters

Each protection zone detects three conditions: Open, Normal, and Short. Listed below are voltage and

resistance parameters for each condition:

Condition

Resistance on zone

Voltage on zone terminal

Open

over 1300 Ohms

over 2.0 VDC

Normal

600 to 1300 Ohms

1.2 to 2.0 VDC

Short

under 600 Ohms

under 1.2 VDC

16.3 Zone Response Time

A condition must be present on a zone for 500 milliseconds before it is detected by the XR2500F panel.

Ensure detection devices used on the protec tion zones are rated for use with this delay. Zones 1-10 can also

be programmed for a fast response delay of 160 milliseconds.

16.4 Keyswitch Arming Zone

Using a keyswitch on an Arming type zone allows you to arm and disarm selected areas without having to

enter a user code.