J11 annunciator outputs, 1 description, 2 model 300 harness wiring – DMP Electronics XR2500F User Manual

Page 33: 3 model 860 relay module, J23 6-pin header

Advertising
background image

XR2500F Installation Guide

Digital Monitoring Products

25

InstallatIon

J11 Annunciator Outputs

18.1 Description

The four programmable annunciator outputs can be programmed to indicate the activity of the panel zones

or conditions occurring on the system. Annunciator

outputs do not provide a voltage but instead switch-

to-ground a voltage from another source and are rated at a maximum 30 VDC @ 50mA. The outputs can

respond to any of the conditions listed in the Description section of Dry Contact Relay Outputs.

18.2 Model 300 Harness Wiring

Access the open collector outputs by installing DMP 300 Harness on the 4-pin header labeled J11. The

output locations are shown below.
Note: For UL applications, devices connected to the outputs must be located within the same room as

the panel.

Output

Color

Wire

Output

Color

Wire

3

Red

1

5

Green

3

4

Yellow

2

6

Black

4

18.3 Model 860 Relay Module

Connect a Model 860 Relay Module to the J11 on the XR2500F panel to provide relays for outputs 3-6. Use

these relays for electrical isolation between the alarm panel and other systems or for switching voltage

to control various functions. Power is supplied to the relay coils from a single wire connected to the

panel auxiliary power terminal 7. The module includes one relay and provides three additional sockets for

expansion of up to four relays. Mount the 860 inside the panel enclosure using the 3-hole pattern and plastic

standoffs. Refer to the 860 Module Install Sheet (LT-0484) as needed.
Model 305 Relay Contact Rating:

1 Amp at 30 VDC (allows .35 power factor)

J23 6-Pin Header

19.1 Description

The XR2500F Command Processor™ panel supports RS-232, LX-Bus and Wireless Bus expansion operation.

These operations cannot function at the same time. Install a jumper on one pair of J23 headers to indicate

how the panel is programmed to operate. Refer to the table below when installing a jumper on J23. When

a jumper is installed or moved on the 6-pin header, briefly reset the panel using the J16 jumper to activate

the selected operation.

J23 6-Pin Header

Letter

Operation

R

Standard RS-232

L

LX-Bus

X

Wireless Bus

LEDs

Xmit

Rec

J22

LX

J23

J21

RS-232

R

L

X

Overcurrent

(OVC) LED

Figure 14: J23 6-Pin Header

Advertising