Listed Compliance Specifications

24.1 Introduction

For applications that must conform to a local authorities installation standard or a National Recognized Testing

Laboratory certificated system, please see the following sections.

Universal UL Burglary Specifications

25.1 Introduction

The programming and installation specifications contained in this section must be completed when installing

the XR2500F panel in accordance with any burglary standards. Additional specifications may be required by a

particular standard. See the XR500 Programming Guide (LT-0679).

25.2 Wiring

All wiring must be in accordance with NEC, ANSI/NFPA 70, ANSI/UL 681. All transformer wires must be

installed in conduit.

25.3 Control Outside of Protected Area

A Potter EVD or Sentrol 5402 should be used in place of a lined cabinet when the panel is installed outside

of the protected area. Front and rear tamper switches are required. Refer to the system wiring diagram

and Figure 2.

25.4 Police Station Phone Numbers

The digital dialer telephone number programmed for communication must not be a police station phone

number.

25.5 Bypass Reports

The Bypass Reports option must be programmed as YES for all listed burglary applications.

25.6 System Maintenance

To ensure continuous satisfactory operation of any alarm system, proper installation and regular

maintenance by the installing alarm company and frequent testing by the end user is essential. Offering a

maintenance program and acquainting the user with the correct procedures for system use and testing is

also the responsibility of the installing alarm company.

25.7 Listed Receivers

Operation has been verified with the DMP SCS-1R, Sur-Gard SG-HLR2-DG, FBII CP220PB, Osborne-Hoffman

Quick-Alert, and Radionics D6500 receivers. It is the installer’s responsibility to verify compatibility between

the XR2500F and the receiver used during installation. The installer shall verify the compatibility of the

receiver and the system on a yearly basis.

25.8 Power Supply Supervision

For commercial burglary applications the power supply for all local bells shall be under 24-hour protection.

Refer to the Secondary Power Supply section in this document.

25.9 Wireless Tamper

The Zone Information Disarmed Open Message to Transmit must be programmed Trouble (T). (Not applicable

to ANSI/UL 1023).

25.10 Wireless External Contact

When used, the External Contact of 1101 or 1102 must be programmed Normally Closed.

25.11 Wireless Supervision Time

The Zone Information Supervision Time cannot be set to 0 (zero).

25.12 Detect Wireless Jamming

The Detect Wireless Jamming option must be programmed YES. (Not applicable to ANSI/UL 1023).