Revisions to this document – DMP Electronics XR2500F User Manual

Page 58

Advertising
background image

Digital Monitoring Products

XR2500F Installation Guide

50

RevIsIons

Revisions to This Document

This section explains the changes made to this document during this revision. It lists the version and

identifies the change(s) made, the related section number and section heading, and a summary of the

change.

Ver Section Number and Heading

Quick Explanation of Changes

1.03 31.4 Bell

Added mercantile information

32.4 Mercantile Safe & Vault

Removed section

32.4 Bell

Added mercantile information

32.6 Bank Safe

Removed section

1.02 The following changes were implemented for ANSI/UL 864 9th Edition compliance

Complete Document

Removed all references to the 504-24 Power Supply

1.1 Overview

Added reference to optional power supply

1.3 Power Specifications

Added reference to Compliance Instruction section

1.7 LX-Bus

Added reference to 463G

1.8 Outputs

Added output rating

1.11 Compliance Instructions

Added section

2.6 Wiring Diagram

Removed 504-24, 24 VDC batteries, and transformer

Updated Types of Service

3.1 Transformers and AC Power

Removed 100 VA transformer

5.2 Connection

Added reference to optional power supply

Updated Figure 5 for Notification Appliances

5.4 Notification Appliances

Moved to Compliance section

6.8 Power Requirements

Updated 710, 711, 716, 866, and 867 current draw

7.4 Digital Dialer

Added maximum impedance

10.1 Wiring Diagram

Replaced 790F keypad with 630F

10.3 Accessory Devices

Added 463G, updated 865, 866, 867, and 869 descriptions, removed

reference to 690F, and 790F.

11.7 Standby Battery Calculations

Added 463G, and 7100 keypads

11.8 Standby Battery Selection

Added 341, and 352S as optional battery enclosures

12.1 Terminal 5 and 6

Added reference to Notification Appliance section

13.2 Terminal 7 - RED

Added reference to Power Supply section

15.1 Terminals 25-26 and 27-28

Added maximum voltage, maximum normal standby, maximum line

impedance, and ground fault detection

17.2 Contact Rating

Added power factor statement

18.1 J11 Description

Added maximum ratings

18.3 Model 860 Relay Module

Added power factor statement

19.1 J23 Description

Added Wireless Bus reference

24.1 Listed Compliance Specification

Added section

25.8 - 26.12 Universal Burglary

Added sections

27.7 Wireless Audible

Added section

28.8 - 28.13 ANSI/UL 1610

Added sections

29.1 - 29.8 ANSI/UL 636

Added sections

31.8 - 31.13 ANSI/UL 365

Added sections

32.1 - 32.7 ANSI/UL 609

Split from ANSI/UL 365

35.1 Power Supply

Added section

35.9 Fire Protective Signalling

Updated to reflect current panel programming options

35.10 - 35.14 ANSI/UL 864

Added sections

38.4 Communication Programming

Updated to reflect current panel programming options

39.1 - 39.7 Wiring Diagrams

Added wiring diagrams

39.10 Wiring Diagrams

Added reference to 463G

39.11 Wiring Diagrams

Removed reference to 867 module