Menu basic setting functions – MBM Corporation 352SA automatic air suction folder with Register System User Manual
Page 30
Operator's Manual multimaster CAS 35 PBA
Automatic Setting
Mathias Bäuerle GmbH
31
Menu BASIC
Setting Functions
Menu BASIC
Setting Functions
The following adjustments can be made in the BASIC menu:
With the machine running:
Fine adjustments for:
Fold length in fold plate 1
Fold length in fold plate 2
Position of delivery rollers
in delivery section
74.0
148.0
74.0
1
2
Basic settings for:
Machine speed
Length of shingle on delivery
70
20 mm
%
To edit information displayed, mark the respective field by pressing the cursor
key , then change the value using the key.
Sheet gap on register table
20 mm
If the sheet gap is set to smaller than 10 mm, the machine automatically
switches to "Continuous suction" and the display shows:
By pressing key (+ ), it is possible to return from continuous
suction to pulsed operation.
OFF
Erasing
Total counter
437
For erasing the total counter, mark the icon with the
cursor key .
The press key .
The display alternately shows the current count
and the symbol .
The counter is reset by pressing the key.
437
437
= 0