Possible malfunctions and their remedies – MBM Corporation 352SA automatic air suction folder with Register System User Manual

Page 64

Advertising
background image

Operator's Manual multimaster CAS 35 PBA

Mathias Bäuerle GmbH

65

16. Possible Malfunctions and their Remedies

Error:

see no.

Intermittent and irregular paper feed

1

2

Creasing

3

4

5

6

7

Several sheets are fed together

8

9

10

Sheets are not transported up to fold plate stop

11

Feeder does not start

12

13

14

Skewed folds

15

Points

16

Fold variations

17

18

Paper jam in delivery section

19

20

21

Folder does not start

22

No.

Possible Cause

Remedy

1

Air brackets are set too narrow

Set with a little more side play

2

Vacuum too low

Increase vacuum by opening the corres-
ponding valve a little more

3

Speed too high

Reduce speed

4

Sheets are not fed at right angles

Align register rail

5

Pressure of first pair of fold rollers

Have pressure and parallel alignment

too strong or uneven

set by service technician

6

Too many steel balls in ball cage

Use more plastic balls

of register rail

7

Insufficient guidance by balls

Shift ball cages

8

Front paper stop is not set to the

Change height by means of setting screw

correct height

9

Vacuum too strong

Reduce vaccum

Advertising
This manual is related to the following products: