5.3.4 REAL-TIME CLOCK
^A

^D

Command

30

Change Clock: Use the sequence below to set the time and date of the optional
real-time socket:

^D305
HH:MM:SS5
DD/MM/YY/W5

HH = hours (24 hour format)

MM = month

MM = minutes

DD = day of month

SS = seconds

YY = last 2 digits of

year

W = day of the week
1 = SUN
2 = MON
3 = TUE
4 = WED
5 = THR
6 = FRI
7 = SAT

The clock produces a string of text that is accessed through use of a TSN of 0
(See Table 10 for definitions of field parameters).

The text string is shown below...

HH:MM:SS MM/DD/YY XXX DD/MM/YY XXX

...where xxx is the day of the week.

These values should be inserted into the Field parameters for proper clock text access:

Clock Field Parameters

TSN

TSP

CC

TEXT

0

1

8

HH:MM:SS

0

10

8

MM/DD/YY

0

19

3

Day of Week

0

23

8

DD/MM/YY

0

32

3

Day of Week

Table 10