5.3.5 SERIAL NUMBER COMMANDS
The following commands, ^D80 through ^D89, refer to the serial numbering functions of the
470 printer. The 470 can increment or decrement any single serial number by any amount.

^A

^D

Command

80

Disable all serial numbering.

XX

81

Disable Single Serial Number Field: Will disable an individual serial number
field.

XX

82

Enable Single Serial Number Field: Will recall a stored serial number (1-16)
and place it into an individual serial number field on the label. XX determines
the stored serial number slot to be recalled. The TSN (Text String Number) is
selected by following the ^AXX^D825 with the TSN surrounded by quotes
("TSN"5). This command is not stored between labels, it must be sent each time
a format is sent and must be located after the ^D57 command and format
information.

XX

83

Select Stored Serial Number to increment: Tells the printer which stored serial
number to increment. See section 4.5 on text string numbers. The ^A value
states which serial number is selected.

XX

84

Select Stored Serial Number to decrement: Tells the printer which stored
serial number to decrement. See section 4.5 on text string numbers. The ^A
value states which serial number is selected.

85

Clear All Stored Serial Numbers: This function will erase any serial numbers
stored in memory.

XX

86

Load New Serial Number Into Memory: This command loads a serial number
into non-volatile user memory. XX is used to select the serial number slot (1-16).
The actual serial number, up to 9 characters, is placed in quotes and follows the
^AXX^D865.

XX

87

Load Increment/Decrement Value Into Non-Volatile User Memory: Will load
and store a step value into non-volatile user memory. The stored serial number
to be affected is chosen with the XX variable and the actual step value, up to 9
characters, is entered by following the ^AXX^D875 with the step value
surrounded by quotes.

XX

88

Send Serial Number To Serial Port: ^A specifies which stored serial number
(1-16) to send.

XX

89

Send Increment/Decrement Value To Serial Port: ^A specifies which stored
increment/decrement value (1-16) to send.