4. Installation

4-1

4.1 Place and Conditions of Unit Installation

Exhaust gas from the engine is poisonous, and could
cause death when inhaled.

Avoid using the machine in an insufficiently ventilated

building or tunnel.


The machine must be installed on dry, firm and level
area.

In case the machine has to be installed on a slope, keep

the inclination angle less than 5 degrees.

Avoid installing the machine in a place such as a damp

area or a place where puddles might form after rain.
Such an installation could cause electric shock.

Do not direct the exhaust gas outlet to nearby personnel
or houses in the vicinity.

When installing the machine at salt water areas or on a
ship, make sure the machine is not exposed directly to
sea water.

When installing the machine at sandy area, make sure
that exhaust from the generator or radiator does not blow
the sand in the air, or into the machine.

The machine should be operated in following conditions:

Ambient temperature

5°F

to 104°F

(

–15℃ to +40℃)

Humidity

Less than 85%

Altitude

Lower than 1,640ft (500 m) above sea level

If more than two machines are placed parallel in
operation, keep enough distance so that exhaust air
from one machine does not effect the other one.

Keep enough space around the unit for inspection and
maintenance access.



Ventilation

PC002

Installation

SG0103

SG0110

40(1000)
or more

Unit :

40(1000)

or more

40(1000)

or more