5. Operation

5-3

Fire prevention

Taking off the radiator cap

5.1.3 Check Coolant Level


Be sure to stop the machine and allow time to cool. Loosen the

radiator cap one notch. After the coolant water is sufficiently

cooled and the inner pressure is released, slowly remove the

cap.

If this procedure is neglected, the inner pressure can blow the

cap off. Steam jetting out of the radiator could result in a

serious scalding injury.

Check the coolant level in the reserve tank. If it is lower than
the limit, open the cap and replenish the coolant. (Level must
be kept above LOW mark.)

If little coolant is left in the reserve tank, replenish the
radiator with coolant. (See 6.9.1)

5.1.4 Check Fuel


Do not, under any circumstance, smoke cigarettes or
light matches during fueling.

Fuel is extremely flammable and dangerous. It is,
therefore, very easy to start a fire when you handle fuel
around flames or sparks.

Refuel only after stopping the engine, and never leave
an open fuel can near the machine. Do not spill. It could
cause a fire. If fuel is spilled, clean it up completely.

Fuel refilling should be done in an outdoor
well-ventilated area.


Be sure to use diesel fuel oil for diesel engine.

(Using other oils may cause low power or damage to the engine.)

Check fuel gauge for low level before operation. Replenish enough fuel to prevent fuel
shortage during operation.

Be sure to fasten the fuel tank cap firmly after refilling. If fuel is spilled, clean it up
completely.

D004

H990432

SG0122

Choose appropriate fuel

Low

Reserve tank