5. Operation

5-4

5.1.5 Drain Fuel Tank

Open drain valve at the bottom of the fuel tank to
discharge condensation left in the tank.

With condensation completely drained, firmly close
the drain valve.

Dispose of properly according to designated
regulations.





5.1.6 Check Condensation in Water Sedimenter

Check if the red float in the water sedimenter rises up to the water drain level, mark drain
water if it is near the maximum drain level.

(1) SDG25S

(Procedure)

Close the valve lever on the upper part of the
sedimenter.

Loosen the ring nut to remove the bowl.

Carefully remove the bowl because it contains fuel.

Be careful not to spill fuel and soil the machine

interior.

After draining condensation, clean the bowl, and
re-install.

Turn the valve lever to "OPEN" position to refill fuel
and bleed air. (See 5.5)

(2) SDG45S/60S/75S/100S

(Procedure)

Loosen the drain plug to drain the water from the
sedimenter.

After draining condensation, fasten the drain plug
securely.

SDG25S

SG0124

Drain level

Float (red ball)

Drain plug

CLOSE

Valve lever

Ring nut

Drain level

Float(red ball)

H990046

OPEN

H990309