H36PVN Power Vent Indoor Gas Fireplace

Page 10

XG0649 - 031511

Installation

Venting Components

The following venting components and associated Montigo part

numbers are available for the EDVRSPV58

:

Connection and installation of the vent components

should adhere to the following guidelines:

„

Connect all vent sections using a minimum of three sheet

metal screws on the outer pipe flue .

„

Ensure the pipe ends male to female slide in a minimum

of 1 1/2“ of overlap .

„

Ensure all runs are supported with a minimum of 3 supports

per 10’ of venting .

„

When hanging/ supporting venting, ensure that 1” clearance

is maintained on all sides to any combustible material .

„

Ensure when cutting sections of rigid pipe to maintain

integrity of internal supports .

„

Place the springs, supplied with the pipe kit, between the

outer and inner pipes to keep the pipes separate and avoid

any possible hot spots .

„

Montigo recommends the use of a flex section for the final

pipe connected directly to the fireplace offering greater

flexibility of installation and absorption of movement .

„

All exterior joints in venting should be sealed with high heat

silicone 706 High Temp .

A - Termination

EDVRSPV58

B - Rough-in Frame

EDVRSPV58F

C - Flex Sections

PLF-1 (12" Section)

PLF-2 (24" Section)

PFL-3 (36" Section)

PFL 4 (48" Section)

D - Rigid Sections

PEXT-1 (12" m/f Section)

PXT-20 (20" Section)

PEXT-2 (24" m/f Section)

PEXT-3 (36" m/f Section)

PEXT-4 (48" m/f Section)

E - Elbows

PEL-90MM (m/m 90

º Elbow

PEL-90FF (f/f 90

º Elbow

PEL-90FM (f/m 90

º Elbow)

PEL-45FM (f/m 90

º Elbow)

F - Power Cord

Harnesses

EPVH10-10 foot power cord & harness

EPVH20-20 foot power cord & harness

EPVH30-30 foot power cord & harness

EPVH40-40 foot power cord & harness

EPVH50-50 foot power cord & harness

EPVH60-60 foot power cord & harness

EPVH70-70 foot power cord & harness

EPVH80-80 foot power cord & harness

EPVH70-70 foot power cord & harness

EPVH70-70 foot power cord & harness

EPVH80-80 foot power cord & harness

EPVH90-90 foot power cord & harness

EPVH100-100 foot power cord & harness

Installation of the EDVRSPV58 External roof mounted power vent

module.

Refer to Appendix A - Power Vent locations, to ensure the planned

Vertical Power vent location is acceptable .

The EDVRSPV58F Rough-in Frame dimensions:

The EDVRSPV58 Power Vent dimensions:

Top View

Front View

Ø14”

8 1/2”

19 1/4”

Ø 1/2”

2”

18”

18”

Top View

Front View

Ø 8”

14”

6”

18”

18”