Maintenance, Removing the log grate, Removing the refractory – Montigo H36PVN User Manual

Page 30

Advertising
background image

H36PVN Power Vent Indoor Gas Fireplace

Page 30

XG0649 - 031511

Maintenance

1

2

Removing the Log Grate:

The

H36PVN is supplied with a log Grate that is fastened directly to

the base of the Fireplace . To remove the Grate, to perform certain

Maintenance functions, follow the steps described below:
Step 1. CLOSE GAS VALVE AT INCOMING TO FIREPLACE, (By

Qualified Persons ONLY, See 'Before You Start' in the Index).

Step 2. Remove the two (2) machine screws that hold the Pilot

Assembly in place, Figure 20 . (Philips head screwdriver required).

Figure 20. (Pilot mounting machine screws).

3

Step 3 & 4 Remove the two (2) (RH & LH) Base mounting machine

screws, Figure 20a & 20b . (Philips head screwdriver required).

Figure 20a. (LH Base mounting

machine screw).

4

Step 5. Loosen, and Remove the Flexible Gas hose (at fitting),

(turn clockwise, left to right) Figure 20c & 20d . (3/4" Open end

wrench required).

5

5

Figure 20b. (RH Base mounting

machine screw).

5

1

2

3

4

Figure 20c. (Gas fitting).

NOTE: Ensure all 5-steps are complete before removing Log Grate.

(Failing to do so may damage the flexible gas hose, or mounting

hardware of the grate).

Figure 14e.

Figure 20d. (Loosening Gas fitting

on burner).

Removing the Refractory:

The

H36PVN is supplied three (3) pieces of firebox refractory Lining .

These panels are fastened directly to the interior sides, and back

of the Fireplace firebox with brackets . To remove the brackets and

panels follow the steps described below:
Step 1. Remove the RH-TOP machine screw that hold the Side

Refractory panel in place, then the bottom, Figure 22 . (Philips head

screwdriver required).
Step 2. Remove the RH-Refractory panel from the firebox, Figure

22 . (Place the Refractory panel somewhere safe where it will not

get chipped or damaged).
Step 3. Follow step1 & 2 to remove the LH-Side Refractory panel,

Figure 22 . (Philips head screwdriver required).

Figure 20e. (Log Grate Removal Sequence).

Figure 22. (Removing Refractory panels).

Step 1 & 2. Figure 20. (Pilot mounting

machine screws).

Step 3 & 4. Figure 20a. (LH Base

mounting machine screw).

Figure

20b. (RH Base mounting machine

screw).

Step 5. Figure 20c & 20d . Loosen, and

Remove the Flexible Gas hose (at

fitting), (turn clockwise, left to right)

(

3/4" Open end wrench required).

LH-Panel

RH-Panel

Back-Panel

Bottom

Brackets

Top

Brackets

Advertising