Warning, Caution, Operation – Montigo H36PVN User Manual

Page 28

Advertising
background image

H36PVN Power Vent Indoor Gas Fireplace

Page 28

XG0649 - 031511

Operation

Section 9: Start-up Sequence

STARTUP SeqUenCe:

1) Turn the wall switch ON

2) The blowers will start and within 10 seconds the glow plugs will

start to glow

3) If the pilot does not light the gas valves willl turn the glow plugs

off after 20 seconds

4) This may need to be done three or four times to bleed all of the

air out of the gas lines within the fireplace

5) Turning the switch OFF and then ON again will reset this start

up sequence

6) Once the pilots are burning the main burner will turn on and

the fireplace will be functional for a quick start up on next use .

If the information in these instructions is

not followed exactly, a fire or explosion

may result causing property damage,

personal injury or death.

WARNING

XW2008

■ This fireplace has been set up at the factory for a

determined air volume though the venting system.
■ This fireplace will not operate unless the correct

air movement is detected by our control system..
■ Please consulted with your contact person at

Montigo should you have any problems with your

start up.

CAUTION

XW2040

Advertising