Warning, Installation – Montigo H36PVN User Manual

Page 11

Advertising
background image

H36PVN Power Vent Indoor Gas Fireplace

Page 11

XG0649 - 031511

Installation

Figure 5. Construction, Rough-in framing.

Step 1.

Construct a Vertical Chase for the termination opening to meet

the following requirements:

■ Opening Size must be:

14 1/2" x 14 1/2" x 18" Min . height .

Step 2.
Install the Vent pipe female end up, and 2" to 3" MAX . from the

top of the Constructed Chase . Also, at this point install the Electrical

harness, (EPVH-(10-100) that will communicate with the Power

Vent Module .

Figure 5a. Installation, Vertical Vent pipe . (female end top end).

Figure 5b. Installation of Rough-in Kit

Step 3.
Install the Power Vent Rough-in Kit . Pull wire harness through

the supplied hole in the bottom corner of the rough-in box, and snap

into the slot provided, (See figure 5b inset) .

Figure 5c. (Fasten Rough-in Kit to framing)

Step 4.
Install fasteners around perimeter of Rough-in Kit . (Holes supplied

for ease of installation)

Figure 5d. (Installed Stainless steel cover)

Installing the external roof mounted power vent module

All venting material must be sealed with high heat

silicone sealant RV230. All venting material to be

Montigo flex pipe, with as few joints as possible.

All joints use MVA vent splice, sealed thoroughly

with silicone. Montigo will not be held responsible

for any water damage that may occur from not

installing the equipment as specified by this

document.

WARNING

XW2024

14½"

14½"

18"

Vent Chase

Electrical Harness

with connection

2" to 3" Max.

Vent Pipe

Power Vent

Rough-in Kit

Electrical

Harness

Electrical Harness

Connerctor Location

Install Fasteners around

perimeter of Rough-in Kit