Installation

Venting Components

The following venting components and associated Montigo part

numbers are available for the EDVWSPV58:

Connection and installation of the vent components should

adhere to the following guidelines:

■ Connect all vent sections using a minimum of three sheet

metal screws on the outer pipe flue .

■ Ensure the pipe ends male to female slide in a minimum

of 1 1/2“ of overlap .

■ Ensure all runs are supported with a minimum of 3 supports

per 10’ of venting .

■ When hanging/ supporting venting, ensure that 1” clearance

is maintained on all sides to any combustible material .

■ Ensure when cutting sections of rigid pipe to maintain

integrity of internal supports .

■ Place the springs, supplied with the pipe kit, between the

outer and inner pipes to keep the pipes separate and avoid

any possible hot spots .

■ Montigo recommends the use of a flex section for the final

pipe connected directly to the fireplace offering greater

flexibility of installation and absorption of movement .

■ All exterior joints in venting should be sealed with high heat

silicone RV230 .

Installation of the EDVWSPV58 external wall mounted power vent

module.

Refer to Appendix A - Power Vent locations, to ensure the planned

Vertical Power vent location is acceptable .

The EDVWSPV58 Power Vent dimensions:

The EPVF58 Rough-in Frame dimensions:

9 3/4"

10 9/16"

5

9.0

11 1/16"

11 1/16"

11 1/16"

10 9/16"

5

9.0

14 1/4"

14 1/16"

1 1/2"

4 9/16"

8

12 1/8"

9 11/16"

12 5/16"

4

9 11/16"

ISOMETRIC VIEW

EPVF58 DIMS (2).pdf 1 3/7/2011 9:16:30 AM

A - Termination

EDVRSPV58

B - Rough-in Frame

EDVRSPV58F

C - Flex Sections

PLF-1 (12" Section)

PLF-2 (24" Section)

PFL-3 (36" Section)

PFL 4 (48" Section)

D - Rigid Sections

PEXT-1 (12" m/f Section)

PXT-20 (20" Section)

PEXT-2 (24" m/f Section)

PEXT-3 (36" m/f Section)

PEXT-4 (48" m/f Section)

E - Elbows

PEL-90MM (m/m 90

º Elbow

PEL-90FF (f/f 90

º Elbow

PEL-90FM (f/m 90

º Elbow)

PEL-45FM (f/m 90

º Elbow)

F - Power Cord

Harnesses

EPVH10-10 foot power cord & harness

EPVH20-20 foot power cord & harness

EPVH30-30 foot power cord & harness

EPVH40-40 foot power cord & harness

EPVH50-50 foot power cord & harness