17

Set up the background application

From IBM POS main screen:

1. Press ALT+SysRq.

2. Press B, and then press Enter.

3. Press F8 to start application.

4. Exit and save.

Activate the changes

From IBM POS main screen

1. Press 4 [enter].

2. Press 1 [enter].

3. Press 4 [enter].

The system will configure the changes; this may take a few minutes

DVR / NVR Server Side Setup

1. Click Setup on the Main Display screen of the DVR or NVR Software.

2. Click General in Setup.

3. Click the POS Setup button to open the POS Setup window.

4. Click the Setup POS Agent button in the POS Setup window to open the Communication Status window.

5. Set the Protocol to Catalina(IBM 4680/4690) in the Communication Status window and click Setup.

6. In the Save tab select the Save Location and configure the other save options then click Apply.

7. Click the Communication tab and set the POS ID to the register number you are connecting to and the Type as UDP Server.

8. Click Add to open TCP/UDP Communication window.

9. In the TCP/UDP Communication window, enter the TCP\IP Port used in step 4 of the Catalina options above into the Local

Port box.

10. In the TCP/UDP Communication window, confirm that the Match Workstation ID check box is selected and enter the register

ID in the Workstation ID box.

11. Click OK

12. Repeat steps 7-10 until all registers have been added then click the Apply and OK button.

13. Click OK to close the Communications Status window.

14. In the POS Setup window select a camera under Channel and assign it a register under POS.

15. Repeat step 13 until all registers have been assigned to a camera.

16. Click OK to save the current setting and close the POS Setup window.

17. Click Exit in the Setup Menu to return to the Main Display. Incoming transaction data should now be displayed on cameras with