System configuration operation – REMKO KWL 130 H User Manual

Page 7

Advertising
background image

System configuration

Operation

The system can be easily operated
via the fully automatic iChiLL
controller. If due to local conditions
programming via the internal
control can only be realised with
difficulty, the system can also be
controlled via a cabled remote
control (accessory) or an external,

If the letter "A" is shown in

the display with a two-digit

numeric code, there is a fault

in the chiller. (see chapter on

trouble-shooting and customer

service).

!

CAUTION

The unit is designed as a 2 conduc-

tor system.

The system has 2 medium pipes

(conductors: supply and return)

for cooling using a cold medium

(KWL) or heating using a warm

medium (units with HP function

KWL...H).

In combination with a correspond-

ing system, the output can be

transmitted to the room to be

cooled via the floor, the building

structure or by means of ceiling

cooling.

For each of the different systems,

a minimum flow volume and

a minimum medium volume must

be ensured for the plant.

Chiller

System configuration

Medium intake

Medium outlet

Indoor area 1

Outdoor area

Indoor area 2

Indoor area 3

Room temperature control

Infrared remote control

Cabled remote control

Chilled water -

appliance

Chilled water -

appliance

Chilled water -

appliance

Condensate drain

Condensate line (only

units with HP-function)

Condensate drain

Condensate drain

Condensate collecting pipe

v

Methods of operation

Centralised

fault signal

iChiLL controller

Cable

remote control

Enabling contact

On/OFF Cooling/Heating

(e.g. building management

system)

(Standard equipment)

(Standard equipment)

(Accessories)

(Standard
equipment)

Help save on energy consump-

tion in stand-by mode! If the

device, system or component

is not in use, we recommend

disconnecting the power sup-

ply. Components with a safety

function is excluded from our

recommendation!

TIP

NOTE

The escape of refrigerant con-

tributes to climatic change. In

the event of escape, refrigerant

with a low greenhouse poten-

tial has a lesser impact on glo-

bal warming than those with a

high greenhouse potential.

This device contains refrige-

rant with a greenhouse poten-

tial of 1975. That means the

escape of 1 kg of this refrige-

rant has an effect on global

warming that is 1975 times

greater than 1 kg CO2, based

on 100 years. Do not conduct

any work on the refrigerant

circuit or dismantle the de-

vice - always enlist the help of

qualified experts.

potential-free, enabling contact
(standard).

A centralised fault contact, part of
the standard equipment, can be
used for the external signalling of
a fault.

7