6620-3200

&F – Load factory defaults
Factory default will be loaded, ISDN protocol setting and msn’s will not be overwritten. 
(for storing in non volatile memory please use the command AT&W).

AT&F0 

Setup all parameters concerning data port

AT&F1 

Setup all parameters including ISDN protocol and msn settings.

!&F – Load factory defaults
Factory default will be loaded for the analogue option  
(for storing in non volatile memory please use the command AT!&W).

AT!&F 

The analogue modem loads the factory default configuration (profile)

H – Disconnect
Disconnects existing ISDN data connection, after issuing the Escape sequence (+++).
To enter the ATH command during an active data connection you must use the follow-
ing sequence "<1 sec pause> <+><+><+> <1 sec pause>" to reach the online command 
mode.
The time gap between all three plus signs may not exceed 1 sec. 
The escape sequence is transmitted transparently to the remote device.

 The timeout after sending the "escape sequence" <+><+><+> will increase if the 
configuration parameter "txfwd" will rise. The default value of "txfwd" is set to "0".

I – Display version information
Displays different information about version number and settings:

ATI0 

 Returns the “Modem”-type; name of the terminal adapter (“IDW-
90“)

ATI1 

Returns internal checksum 

(“??”)

ATI2 

Returns “OK”

ATI3 

Returns version string:

 “410045vv”

 vv = version number.

ATI4 

Returns manufacturers name: “Westermo Teleindustri AB”

ATI5 

Returns ISDN selected D-Channel protocol: “0 – DSS1”

ATI6 

Returns copyright string: “(c) Copyright Westermo Teleindustri AB”

ATI7 

 Returns the status of the IDW-90 configuration switches.

1 

1 

1 

1

“00000000.00000000.00000000.00000000”

SW1 

SW2 

SW3 

SW4

‘0’ = switch OFF and ‘1’ = switch ON.

ATI9 

Returns plug and play ID string

ATI99 

Returns software version creation date